nav_sec3_new.jpg (651 bytes)
Description   |   Features   |   Size   |   Outputs   |   Specifications   |   Mechanical

SNP-9038
30W Universal Input Power supply

View Specifications in PDF Format
30W Universal Input Power supply
90~260 VAC Continuous Universal Input

 

Description Go to top


The SNP-903 series is a 30W, universal input switching mode power supply. There are various output options, which include triple outputs, dual outputs and single ouputs. It is UL, CSA and VDE approved and complies with the EMI requirements of Vfg 243/1991 and FCC Class B.

Features Go to top

• Small Size / High Power Density
• Continuous Universal Input - 90~260 VAC
• Ample supply of 15V power in a small package
• UL, CSA and VDE approved
• Meets FCC class "B" + Vfg 243/1991
• Typical applications listed below:
• Test Equipment
• Flat Panel LCD Monitors
• printers
• notebook Computers
• gaming equipment
• security apparatus

Size Go to top

2.75 x 5.12 x 1.26 inch
70 x 130 x 32.1 mm

DC Outputs Go to top

Output, V15
Max Load, A2A / 3A pk.
Regulation, %+/-1%
Ripple, mV120

Specifications Go to top
View Specifications in PDF Format

Input VAC
Voltage, V 90-264 continuous
Frequency, Hz 47-63
Current, A 1.5A at 90VAC, 0.75A at 180 VAC
Power Factor N/A
Harmonics N/A
Cooling Free air convection
Power Good N/A
Holdup Time 16 mS minimum @ 115 VAC, full load
Transient N/A
Efficiency 75% typical at full load
Shorted output No damage, auto-recovery
Over Load Protection 4A +/- 0.4A, auto-recovery
Short Circuit Protection auto-recovery
Over Voltage Protection auto-recovery
EMS Consult Factory
Temperature 0 to 40 deg C
EMI CISPR / FCC class B
Safety Agency UL 1950 D3, CSA 22.2 No.234, VDE EN60950

Notes
Go to top
1. The total output current is rated load with free air convection and maximum load.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.

 

Mechanical Go to top

 

 

Click here to view a printer friendly mechanical drawing.
30W Universal Input Power supply
Return to product index

The information and specifications contained in this data sheet are believed to be accurate at the time of publication. If errors are found, they will be corrected. Consequently, specifications may be subject to change without notice.