nav_sec3_new.jpg (651 bytes)
Description   |   Features   |   Size   |   Outputs   |   Specifications   |   Mechanical

SNP-8086-M
80W Universal Input Power supply

View Specifications in PDF Format
80W Universal Input Power supply
90~260 VAC Continuous Universal Input

 

Description Go to top


The SNP-808 series is a 80 watts convection cooling and 100 watts forced air cooling switching power supply,with several options of the output,from single to multiple.

Features Go to top

• Small Size / High Power Density
• Continuous Universal Input - 90~260 VAC
• UL, CSA and VDE approved
• Meets FCC class "B" + Vfg 243/1991

Size Go to top

3.3 x 6 x 1.5 inch
83.82 x 152.4 x 38.1 mm

DC Outputs Go to top

Output+5V+12V
Max Load12A1A
Regulation±1%±5%±5%±5%
Ripple50mV120mV

Specifications Go to top
View Specifications in PDF Format

Input VAC
Voltage, V 85 to 264 VAC continuous
Frequency, Hz 47-63
Current, A see specification
Power Factor N/A
Harmonics N/A
Cooling 80W Free air convection, 100W with 30 CFM forced a
Power Good N/A
Holdup Time 16 mS minimum @ 115 VAC, full load
Transient N/A
Efficiency >70% at full load
Shorted output No damage, auto-recovery
Over Load Protection No damage, auto-recovery
Short Circuit Protection Hiccup mode
Over Voltage Protection auto-recovery
EMS IEC-801-2 8KV air discharge
IEC-801-3 3V/M, IEC
Temperature 0 to °50 C, rated load
EMI CISPR / FCC class B
Safety Agency FCC docket 20780 curve

Notes
Go to top
1. Peak current can be used for 5 seconds maximum at power supply start up. The total continuous output power is the rated load times the voltage with free air convection.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.

 

Mechanical Go to top

 

 

Click here to view a printer friendly mechanical drawing.
80W Universal Input Power supply
Return to product index

The information and specifications contained in this data sheet are believed to be accurate at the time of publication. If errors are found, they will be corrected. Consequently, specifications may be subject to change without notice.