SNP-Z20D
200W U-Channel with Active PFC

View Specifications in PDF Format
200W U-Channel with Active PFC
200W U-Channel with Active PFC

 

Description Go to top


Skynet`s new SNP-Z20 series packs 200W of high efficiency power in a 1U package while maintaining excellent thermal performance. This is made possible by Skynet`s patent pending soft-switching topology which offers up to 87% efficiency in an offline (AC-DC) switcher!

Features Go to top

• 200W Continuous output power in a 1U package
• Up to 87% efficiency!
• 4 watts per cubic inch
• Active power factor correction
• Meets IEC-1000-3-2 harmonics
• EMI: EN55022 Class B

Size Go to top

4.20 x 8 x 1.5 inch
106.7 x 203.2 x 38.1 mm

DC Outputs Go to top

Output+3.3V+5V+12V
Max Load20A / 30A PK15A / 20A PK3A / 6A PK
Regulation±1%±5%±5%
Ripple50mV50mV120mV

Specifications Go to top
View Specifications in PDF Format

Input VAC
Voltage, V 90-264 continuous
Frequency, Hz 47-63
Current, A <20A at 115 VAC
or <40A @ 230 VAC
Power Factor 0.95 minimum at max load
Harmonics EN61000-3-2 class D
Cooling convection cooled
Power Good consult factory
Holdup Time > 20mS at rated load and 115VAC
Transient consult factory
Efficiency 82% ~ 87% - varies by model
Shorted output No damage
Over Load Protection Auto-recovery
Short Circuit Protection Auto-recovery
Over Voltage Protection Latch off
EMS EN61000-4-2,-3,-4,-5,-6,-11
Temperature 0 to 50 degrees C
EMI EN55022
Safety Agency UL60950

Notes
Go to top
1. Each output can provide up to its maximum load separately when the power supply starts up. To exceed the maximum output power rating (200W) continuously is not allowed.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 microfarad capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.
8. +12VB is floating on SNP-Z201 and can be referenced either positive (+) or negative (-).

 

Mechanical Go to top

 

 

Click here to view a printer friendly mechanical drawing.
200W U-Channel with Active PFC
Return to product index

The information and specifications contained in this data sheet are believed to be accurate at the time of publication. If errors are found, they will be corrected. Consequently, specifications may be subject to change without notice.