SNP-Z108
130W 15V 3 x 5 inch air req.

View Specifications in PDF Format
130W 15V 3 x 5 inch  air req.

 

Description Go to top


Skynet’s new flagship product is a 3" x 5" open frame power supply with an amazing power density of 6 watts per cubic inch plus active PFC. The 3” x 5” form factor has been an industry standard for more than 10 years. Initially the power density was around 2 watts per cubic inch then hovered around 3 watts per cubic inch for quite some time. Now the SNP-Z series in 3" x 5" form factor is undoubtedly the current state-of-the-art. With built-in PFC

Features Go to top

• With built-in PFC
• Only 1.35 inch height
• 4.8 Watt per cubic inch
• With ITE & Medical safety
• Efficiency between 80% to 90%
• Operation from 0°C to 70°C by convection

Size Go to top

3 x 5 x 1.28 inch
76.2 x 127 x 32.5 mm

DC Outputs Go to top

Output+15 VDC
Max Load7A / 8.7A pk
Regulation+/-1%
Ripple120mV

Specifications Go to top
View Specifications in PDF Format

Input VAC
Voltage, V 90 to 264
Frequency, Hz 47 to 63
Current, A inrush I <30A at 115VAC;
<60A at 230VAC
Power Factor Active PFC
Harmonics EN61000-3-2
Cooling Free air convection for 100W
18 CFM forced air
Power Good consult factory
Holdup Time 20 mS typical
at rated load and 115VAC
Transient consult factory
Efficiency 80%~90% depending on model
Shorted output Protected
Over Load Protection Auto-recovery
Short Circuit Protection Auto-recovery
Over Voltage Protection Latch-off
EMS EN61000-4-2, -3, -4, -5, -6, -11
Temperature 0 to 50 degrees C
EMI EN55022
Safety Agency UL 60950, CSA 22.2 No. 234 and EN60950

Notes
Go to top
1. The total output current is rated load with free air convection and maximum load. For 130w rating 18 CFM of forced airflow is provided over the unit.
2. Each output is checked at the factory to be within voltage accuracy with a 60% rated load condition.
3. Line regulation is defined by changing the input voltage ±10% from nominal line at rated load.
4. Load regulation is defined by changing the output load ± 40% from 60% of the rated load while another output is set to 60% of rated load.
5. Ripple & noise is measured at rated load and nominal line by using a 15MHz bandwidth limited oscilloscope with each output terminated by a 0.47 uF capacitor.
6. Hold up time is measured from the end of the last charging pulse to when the main output drops down to 95% output voltage.
7. Efficiency is measured at rated load.

 

Mechanical Go to top

 

 

Click here to view a printer friendly mechanical drawing.
130W 15V 3 x 5 inch  air req.
Return to product index

The information and specifications contained in this data sheet are believed to be accurate at the time of publication. If errors are found, they will be corrected. Consequently, specifications may be subject to change without notice.

Home  l   Products  l  Support   l  Sales  l  About Us  l  Contact Us  l  Site Map

nav_sec3_new.jpg (651 bytes)
eUrasia Power,  © 2006, All Rights Reserved
Send email to
for questions or comments about this website.
Last modified: February 15, 2006